跳到主要内容
知仓学习社ZHICANG

iso13485-audit-prep

/cs:iso13485-audit-prep <scope> — ISO 13485 QMS audit 6-question forcing interrogation. Design controls + CAPA + post-market focused. Use before Cla…

不碰外部(只输出文字)无严重或高危命中alirezarezvani/claude-skills

它会碰到什么

扫了多少1 个文本文件,7 KB
它会碰到什么不碰外部(只输出文字)
命中总数0 处
命中统计严重 0 · 高 0 · 中 0 · 低 0

这一栏是扫描器报的事实,不是结论。命中多不等于有毒(安全工具、规则库、示例脚本本来就会包含危险写法),命中少也不等于干净。它和你手上的凭据、文件、网络有什么关系,需要你自己看。

技能内容

/cs:iso13485-audit-prep — ISO 13485 QMS Forcing Questions

Command: /cs:iso13485-audit-prep <scope>

The ISO 13485 QMS auditor pressure-tests any medical-device QMS work. Six traceability-obsessed questions before any internal audit, MDR / FDA QSR review, or product launch.

When to Run

  • Before annual Clause 8.2.4 internal audit
  • Before MDR / FDA QSR alignment review (substantially harmonized post Feb 2026)
  • Before new-device commercial launch (DHF closure audit)
  • After significant CAPA closure event (effectiveness verification audit)
  • Post-recall event (root cause + corrective action audit)
  • Quarterly during regulatory submission preparation

The Six QMS Questions

1. Pull three random DHFs. Are design verification + validation evidence complete?

Most-cited finding area.

  • DHF must include: design plan + inputs + outputs + verification + validation + transfer + changes
  • Sample stratified by product class (I, IIa, IIb, III per MDR)
  • Reference iso13485_audit_playbook.md for the per-DHF checklist
  • Verify traceability matrix from user needs through clinical evidence

2. Show me the last 5 CAPAs with effectiveness verification evidence.

Second-most-cited finding area.

  • Containment / correction / corrective action distinction documented
  • Root cause analysis depth: 5 Why minimum
  • Effectiveness verification = measurable evidence, not "we updated the procedure"
  • Closure approved by appropriate authority
  • Repeat CAPAs across products = systemic issue trigger

3. When was process validation (IQ/OQ/PQ) last revalidated?

Clause 7.5.6 — often stale.

  • Initial validation at process introduction
  • Revalidation triggers: process change, equipment change, material change, periodic schedule
  • Trend monitoring (SPC) where statistical techniques apply per Clause 8.4
  • Cross-check with cs-fda-qsr-auditor for 21 CFR 820.75 alignment

4. Show me the risk management file for the highest-risk product.

Clause 7.1 + ISO 14971:2019.

  • Risk management plan exists per product
  • Hazard identification covers reasonable foreseeable misuse
  • Risk control hierarchy applied: inherent safety > protective measures > information for safety
  • Residual risk evaluated + accepted with rationale
  • Post-production information feeds back into RMF
  • For AI-enabled medical devices: layer ISO 42001 A.5 impact assessment on top

5. Show me post-market surveillance evidence — last 6 months.

Clause 8.2.1 — high-stakes for MDR + FDA.

  • Customer complaint log + investigation closure
  • Vigilance reports (serious incident / FSCA) submitted per applicable regulation
  • Trend analysis evidence + management review input
  • Post-market clinical follow-up (PMCF) for MDR high-risk devices
  • MDR reports per 21 CFR 803 for US-marketed devices (cross-check with cs-fda-qsr-auditor)

6. Where's the management review evidence covering all Clause 5.6 inputs?

Annual minimum; semi-annual for mature programs.

  • Required inputs per Clause 5.6.2: audit results, customer feedback, process performance, product conformity, status of preventive + corrective actions, follow-up from prior reviews, changes that could affect QMS, recommendations for improvement, regulatory requirements
  • Outputs per Clause 5.6.3: improvement decisions, product requirement changes, resource needs
  • Integrated review across frameworks (per multi_framework_audit_playbook.md) preferred

Workflow

# 1. Audit programme optimization
python ra-qm-team/skills/qms-audit-expert/scripts/audit_schedule_optimizer.py audit_scope.json

# 2. Mock audit for readiness check
python ../../skills/compliance-os/scripts/audit_simulator.py iso13485_scope.json

# 3. CAPA system review
# Route to ra-qm-team/skills/capa-officer/ tools

# 4. Risk management file review
# Route to ra-qm-team/skills/risk-management-specialist/ tools

Output Format

# ISO 13485 Audit Prep: <scope>
**Date:** YYYY-MM-DD

## The Decision Being Made
[programme-plan | DHF-closure | CAPA-health | post-market-trend | pre-cert | MDR-FDA-alignment]

## Design Control Status (sampled DHFs)
- DHFs sampled: <list product IDs>
- Verification evidence: pass/fail per DHF
- Validation evidence: pass/fail per DHF
- Clinical evidence (per MDR Annex XIV / FDA 510(k)): pass/fail
- Traceability matrix complete: yes/no per DHF

## CAPA Health
- CAPAs sampled: N
- Root cause analysis depth: adequate/inadequate per CAPA
- Effectiveness verification: complete/incomplete per CAPA
- Aging CAPAs > 90 days: N
- Repeat issues across products: <list>

## Process Validation Status
- Validations on schedule: %
- Stale validations (> 12 months since revalidation): <list>
- Statistical techniques applied per Clause 8.4: yes/no

## Risk Management File Status
- Sampled product RMFs: <list>
- Post-production updates in last 12 months: <count per product>
- Residual risk acceptance signed: yes/no

## Post-Market Surveillance
- Complaint trending: stable/rising
- MDR / vigilance reports filed timely: %
- PMCF on schedule (where required): yes/no

## Management Review Status
- Last review date: YYYY-MM-DD
- Required Clause 5.6.2 inputs present: yes/no
- Open action items past due: N

## Cross-Framework Impact
- EU MDR alignment: clean / gaps in <list>
- FDA QSR alignment (post-Feb 2026): substantially harmonized; FDA-specific overlays per cs-fda-qsr-auditor
- ISO 42001 AIMS overlay (if AI-enabled device): pass/fail per Annex A

## Verdict
🟢 READY | 🟡 CLOSE-DHF-GAPS-FIRST | 🔴 NOT-READY

## Top 3 Actions
[3 concrete next steps with owner + corrective-action timeline]

Routing

  • /cs:compliance-readiness — for multi-framework view
  • /cs:fda-qsr-audit-prep — for FDA-specific overlay
  • /cs:aims-audit — for AI-enabled medical device ISO 42001 layer
  • /cs:gdpr-audit-prep — for personal-data overlap (clinical data, customer data)
  • /cs:cpo-review — for executive product strategy decisions
  • /cs:decide — to log the verdict

Related

  • Agent: [cs-cqm-iso13485](../../agents/cs-cqm-iso13485.md)
  • Skill: [qms-audit-expert](../../../ra-qm-team/skills/qms-audit-expert/SKILL.md)
  • Playbook: [iso13485_audit_playbook.md](../../../ra-qm-team/skills/qms-audit-expert/references/iso13485_audit_playbook.md)
  • Adjacent: ../fda-qsr-audit-prep/, ../aims-audit/, ../compliance-readiness/

Version: 1.0.0

想直接用这个技能?

本站把开放许可(MIT / Apache 等)的技能按仓库打包整理到网盘,点一下转存到你自己的网盘,不用一个个从 GitHub 拉。许可未声明的技能只给原始仓库链接,不打包。

它属于哪个仓库

星标★ 26,030
本站分层T1
该仓技能数846
原文件路径compliance-os/skills/iso13485-audit-prep/SKILL.md

同一个仓库里的其他技能

看这个仓库的全部 846 个技能

同名技能的其他版本

有 2 个不同仓库或目录里都有叫 iso13485-audit-prep 的技能。它们内容并不相同,别混用: