biocompatibility-test-selector
Biocompatibility test selection and protocol recommendation skill based on device categorization
它会碰到什么
扫了多少1 个文本文件,3 KB
它会碰到什么不碰外部(只输出文字)
命中总数0 处
命中统计严重 0 · 高 0 · 中 0 · 低 0
这一栏是扫描器报的事实,不是结论。命中多不等于有毒(安全工具、规则库、示例脚本本来就会包含危险写法),命中少也不等于干净。它和你手上的凭据、文件、网络有什么关系,需要你自己看。
技能内容
Biocompatibility Test Selector Skill
Purpose
The Biocompatibility Test Selector Skill recommends appropriate biocompatibility tests and protocols based on device categorization, supporting biological evaluation planning and test laboratory coordination.
Capabilities
- Test battery recommendation by category
- ISO 10993 part selection guidance
- Test lab capability assessment
- Protocol review checklist
- In vitro vs. in vivo decision support
- Alternative testing approaches (21st century toxicology)
- Cost and timeline estimation
- Sample requirement calculation
- Control material selection
- Test article preparation guidance
- Results interpretation support
Usage Guidelines
When to Use
- Selecting biocompatibility tests
- Planning testing programs
- Evaluating alternative methods
- Coordinating with test laboratories
Prerequisites
- Device categorization completed
- Materials characterized
- Testing gaps identified
- Budget and timeline constraints known
Best Practices
- Prioritize in vitro methods where validated
- Consider 3Rs (Replace, Reduce, Refine)
- Select appropriate positive/negative controls
- Plan for sufficient sample quantities
Process Integration
This skill integrates with the following processes:
- Biological Evaluation Planning (ISO 10993)
- Biomaterial Selection and Characterization
- 510(k) Premarket Submission Preparation
- EU MDR Technical Documentation
Dependencies
- ISO 10993 test standards
- ICCVAM alternative methods
- Test laboratory databases
- Sample preparation guidelines
- Control material sources
Configuration
biocompatibility-test-selector:
test-categories:
- cytotoxicity
- sensitization
- irritation
- acute-toxicity
- subchronic-toxicity
- genotoxicity
- implantation
- hemocompatibility
method-preferences:
- in-vitro-first
- validated-alternatives
- traditional
Output Artifacts
- Test battery recommendations
- Protocol specifications
- Sample requirements
- Cost estimates
- Timeline projections
- Lab capability assessments
- Control material lists
- Results interpretation guides
Quality Criteria
- Tests appropriate for device category
- Protocols reference current standards
- Sample quantities adequate
- Cost estimates realistic
- Timelines achievable
- Alternative methods considered
想直接用这个技能?
本站把开放许可(MIT / Apache 等)的技能按仓库打包整理到网盘,点一下转存到你自己的网盘,不用一个个从 GitHub 拉。许可未声明的技能只给原始仓库链接,不打包。
它属于哪个仓库
星标★ 1,796
本站分层T1
该仓技能数2115
原文件路径
library/specializations/domains/science/biomedical-engineering/skills/biocompatibility-test-selector/SKILL.md